Pressure transmitter

 Pressure transmitter

Yj3051 series Pressure transmitter It is a high-precision intelligent instrument produced by foreign advanced technology. It adopts mature capacitance sensor. It has the characteristics of good long-term stability and high reliability. Through digital technology, the temperature and nonlinearity of the sensor are compensated, which greatly improves the accuracy and range of the sensor. The instrument has HART The communication interface can be tested, configured and calibrated through the specially equipped configuration debugging system, and can also be used with the specially equipped manual operator (and ROSEMONT275 Compatible) on-site configuration and calibration. It is suitable for the measurement of pressure, differential pressure and absolute pressure of all kinds of liquid, gas and steam.

 

Yj3051 series Pressure transmitter Product features:

Yj3051 series pressure transmitter is mainly used to measure the pressure, differential pressure, negative pressure, high static pressure, liquid level and absolute pressure of gas, liquid and steam four 20mA.DC Signal output.

Yj3051 series pressure transmitter includes GP Type (gauge pressure) DP type ( differential pressure ) DR type ( Micro differential pressure ) AP Type (absolute pressure) HP type ( hhp ) LT Type (flange type liquid level transmitter) DP/GP Type (remote differential pressure / Pressure transmitter). The combination of pressure transmitter and intelligent enlarged plate can form intelligent pressure transmitter , It can be achieved by HART The manual operators of the protocol communicate with each other for setting and monitoring.   

1、 3051GP Type of pressure transmitter δ It can be used to measure gauge pressure or negative pressure.

2、 3051AP The absolute pressure transmitter δ One side of the chamber receives the measured absolute pressure signal, and the other side is enclosed into a high vacuum reference chamber. It can measure the absolute pressure of degassing system, distillation tower, evaporator and crystallizer.

3、 3051DP Differential pressure transmitter is mainly used to measure the differential pressure, pressure, liquid level and density of liquid, gas or steam, and then convert it into four 20mA.DC Signal output.   

4、 three thousand and fifty-one Differential pressure transmitter includes DP type ( Basic type ) HP type ( hhp ) and DR type ( Micro differential pressure ) Three types. The combination of the above three types of transmitters and intelligent amplifier board can form an intelligent differential pressure transmitter , It can be achieved by HART The manual operators of the protocol communicate with each other for setting and monitoring.  

5、 3051HP The high static pressure differential pressure transmitter is a kind of differential pressure transmitter which is suitable for petrochemical and power plant 32MPa And can withstand one-way overload pressure without being damaged , Therefore, it can be reliably used for differential pressure measurement of high pressure system.    

6、 3051DR Micro differential pressure transmitter [2] Small differential pressure can be converted into four 20mA.DC Signal, it uses specially designed amplifier circuit board and special temperature compensation technology, stable and reliable performance. It is an ideal product for detecting micro pressure, primary and secondary air volume and air loss in furnace combustion chamber.   

7、 3051LT Flange type liquid level transmitter can be used for precise liquid level measurement of various vessels. There are flat flange and plug-in flange for users to choose. Installation flange standard according to ANSI3 〞、 four Flange rating is 150LB Flange diaphragm material 316L Hastellkin, Monel, tantalum, etc. are suitable for corrosive medium. Our factory can also provide other specifications of installation flange for users.
If the user does not indicate, our factory uses 3150LB Installation flange supply .  

8、 3051DP/GP differential pressure / After the pressure transmitter is equipped with remote transmission sealing device, it becomes 1151DP/GP Remote differential pressure / It still has a pressure transmitter 1151DP/GP differential pressure / It is a reliable measurement method which can avoid the direct contact between the measured medium and the isolation diaphragm of the transmitter
① The measured medium has corrosive effect on the sensitive element of transmitter
② It is necessary to isolate the high temperature measured medium from the transmitter  
③ There are solid suspended solids or high viscosity medium in the tested medium   
(4) the measured medium is easy to solidify or crystallize at the same time when it is led by the pressure pipe  
⑤ To replace the measured medium, the measuring head should be cleaned strictly
⑥ The measuring head must be kept clean and no pollution is allowed.
⑦ Application object: corrosive or viscous liquid
⑧ Note: remote transmitter should not be used in vacuum.

9、 3051DP/GP Remote differential pressure / There are four types of remote pressure transmitter  
① 1191 PFW flat remote transmission device (standard 3″ Working pressure 2.5MPa
② 1191 RTW thread mounted remote transmission device (maximum working pressure 10MPa    
③ 1191rfw flange mounted remote transmission device
④ 1191 EFW plug in barrel remote transmission device (standard 3″ or 4″ , working pressure 2.5MPa

 

Yj3051 series Pressure transmitter Technical parameters:

1. Range ratio: forty 1   

2. Accuracy: the range is three four 5   

3 one one reach ten one For adjusting the range ±0.1%   

4 ten one reach forty one For ±0.05 1+0.1URL/ Range) % range   

5. The range is six seven eight nine 0   

The range ratio is 6 one one reach ten one For adjusting the range ±0.15%   

7 ten one reach forty one When, is ±0.075 1+0.1URL/ Range) % range   

8. Stability : Of the maximum range ±0.15%/6 Months.   

9. Temperature effect: the zero temperature error is within the maximum range ±0.25/55 The total temperature error including zero point and range is ±0.5/55 ℃  

10. Note: for range three nine zero Temperature effect error doubling   

11. Static pressure effect:( DP Zero point error of type I in linear output : Static pressure plus static pressure 10MPa , range four five The zero error of the maximum range is 0 ±0.25% , range three six seven eight The zero error of the maximum range is 0 ±0.5% This is a systematic error , Before installation, zero point of transmitter can be adjusted according to actual static pressure , Eliminate this error. HP Zero point error of type I in linear output : Add static pressure 31.2MPa The zero error is less than that of the maximum range ±2.0% This is a systematic error , Before installation, zero point of transmitter can be adjusted according to actual static pressure , Eliminate this error.   

12. Power supply influence: less than the output range 0.005%/V   

13. Vibration effect: in any axial direction, the frequency is 200Hz The error caused by this method is within the maximum range ±0.05%/g   

14. Load effect: as long as the input voltage of transmitter is higher than 12V There is no load impact in the load work area.   

15. installation position influence: the maximum can produce no more than 0.25kPa This error can be eliminated by correction, which has no effect on the measuring range; the measurement body has no effect on the rotation of flange.

 

Yj3051 series Pressure transmitter Product selection:

YJ3051

Pressure transmitter

code

Measuring range Kpa Mpa

two

0-0.1 1.0KPa 7.0 Mpa

 

code

output

E

Non intelligent( 4-20mA Output)

 

S

Intelligent( HART Agreement)

 

Code name

Structural materials

Flanges and joints

exhaust / Drain valve

Isolation diaphragm

Filling liquid

twenty-two

three hundred and sixteen stainless steel

three hundred and sixteen stainless steel

three hundred and sixteen stainless steel

silicone oil

Code name

static pressure MPa

 

 

A-

one

 

 

 

B-

four

 

 

 

code

option

 

 

M1

0-100% Linear indicator

 

 

 

M2

LED Digital display

 

 

 

M3

LCD monitor

 

 

 

B1

Tube bending mounting plate

 

 

 

B2

Bending mounting plate

 

 

 

B3

Tube installation and safe plate installation

 

 

 

C0

1/2-14NPT Taper pipe internal thread joint

 

 

 

C1

1/2-14NPT Welding impulse pipe at the back of pressure joint Ф14

 

 

 

C2

T-joint M20×1.5

 

 

 

d

Flameproof type d BT4

 

 

 

i

Intrinsically safe type ia CT6

 

 

 

1. material of liquid receiving parts: isolation diaphragm: three hundred and sixteen Stainless steel, Hastelloy C , Monel and tantalum; exhaust / Drain valve: three hundred and sixteen Stainless steel, Hastelloy C And Monel; flange and joint: three hundred and sixteen Stainless steel, Hastelloy C Monel; O Ring: fluororubber, nitrile rubber, ethylene - Propylene;

2. materials of non liquid parts: filling liquid: silicone oil or fluorine oil; bolts: carbon steel galvanized; electrical shell: low copper aluminum alloy; O Ring: nitrile rubber; coating: polyester epoxy resin;

3. Impulse connector: flange pressure port 1/4-18NPT (taper pipe thread); joint pressure port 1/2-14NPT (taper pipe thread);     Electrical connection: with 1/2-14NPT Conduit with threaded end. Weight: with 3.5g (excluding options)

 

Yj3051 series Pressure transmitter Order notice:

1. The model of pressure transmitter can be determined according to the specification table.
2. The numbers and symbols in the optional specification table must be filled in clearly and accurately.
3. If there is positive and negative migration, the migration value must be indicated.
4. If differential pressure transmitter needs to be equipped with three valve group and throttling device, it shall be noted separately.
5. The pressure transmitter is calibrated according to the range specified by the user. If there is no regulation, the user will adjust the transmitter to the maximum range at room temperature.
6. When the station number needs to be marked, it should be indicated when ordering.
7. When choosing the transmitter, it should also be determined according to different flange selection table.
8. If the remote transmitter is to be used in vacuum and high temperature, it should be marked when ordering.
9. Contact medium of pressure transmitter O The materials of the ring are nitrile rubber and fluorine rubber.

 

Yj3051 series Pressure transmitter Quality commitment:

Jinhu Yijia Instrument Co., Ltd. is mainly engaged in electromagnetic flowmeter, vortex flowmeter, orifice flowmeter, magnetic flap level gauge, glass plate level gauge and other products, and provides a one-year warranty for all products. In case of product quality problems (excluding wearing parts or accessories) within one year, they shall be repaired free of charge, and technical support shall be provided free of charge.