electromagnetic flowmeter

 electromagnetic flowmeter

Yj-lde series electromagnetic flowmeter It is a high intelligent flowmeter product developed and designed based on Faraday's electromagnetic induction law. We have made innovation and improvement in the original technology YJ-LDE The measurement accuracy, reliability and stability of the series electromagnetic flowmeter have been improved, and the service life of the electromagnetic flowmeter has been increased. At present, YJ-LDE Series electromagnetic flowmeter is widely used in petrochemical, machinery manufacturing, metallurgical power generation, paper and textile, food and pharmaceutical, sewage treatment, environmental protection supervision and other fields.


Yj-lde series electromagnetic flowmeter Structure:
 Structure of electromagnetic flowmeter

A complete electromagnetic flowmeter usually consists of six parts (see Fig one ):

1. Magnetic circuit system:

It is used to generate magnetic field, usually DC or AC magnetic field. General electromagnetic flowmeter is selected 50HZ Alternating magnetic field generated by power frequency power supply.

2. Measuring catheter:

Its function is to let the measured liquid pass through. In order to make the magnetic flux be shunted or short circuited when the magnetic line of force passes through the measuring tube, the measuring tube must be made of materials with non magnetic conductivity, low conductivity, low thermal conductivity and certain mechanical strength. Non magnetic stainless steel, glass fiber reinforced plastic, high strength plastic and aluminum can be selected.

3. Electrode:

It is used to extract the induced electromotive force signal which is proportional to the measured value. The electrodes are generally made of non magnetic stainless steel and are required to be flush with the lining so that the flow of fluid is not obstructed. Its installation position should be in the vertical direction of the pipeline, so as to prevent the deposition on it and affect the measurement accuracy.

4. Shell:

Generally made of ferromagnetic material, it is the outer cover of the distribution system excitation coil and insulates the interference of external magnetic field.

5. Lining:

There is a complete electrical insulation lining on the inner side of the measuring tube and on the sealing surface of the flange. Its function is to measure the resistance of the tube to corrosion by measuring the tube wall resistance. Lining materials are generally PTFE plastic, ceramic, etc. which are corrosion-resistant, high-temperature resistant and wear-resistant.

6. Converter:

The induced electromotive force signal generated by liquid flow is very weak, which is greatly affected by various interference factors. The function of the converter is to amplify and convert the induced potential signal into a unified standard signal and suppress the main interference signal. Its task is to detect the induced potential signal from the electrode Ex After amplification, it is converted into a unified standard DC signal.

 Electromagnetic flowmeter sensor

 

Working principle of yj-lde series electromagnetic flowmeter:

 Principle of electromagnetic flowmeter

Electromagnetic flowmeter is based on Faraday's law of electromagnetic induction for flow measurement. The advantage of electromagnetic flowmeter is that the pressure loss is very small and the range of flow can be measured. The ratio of maximum flow to minimum flow is generally twenty one Above, applicable to a wide range of industrial pipe diameter, up to the maximum 3m The output signal is linear with the measured flow rate, with high accuracy, and the measured conductivity ≥ five μ s/cm The flow rate of acid, alkali, salt solution, water, sewage, corrosive liquid, slurry, pulp, etc. But it can't measure the flow of gas, steam and pure water.

When a conductor moves in a magnetic field by cutting the magnetic line of force, an induced potential will be generated in the conductor. The magnitude of the induced potential is directly proportional to the effective length of the conductor in the magnetic field and the speed of the conductor moving perpendicular to the magnetic field in the magnetic field. Similarly, when the conductive fluid flows vertically in the magnetic field and cuts the magnetic induction force line, the induced potential will be generated on the electrodes on both sides of the pipe. The direction of the induced potential is determined by the right hand rule, and the magnitude of the induced potential is determined by the following formula:

Ex=BDv---------------- - Formula( one

Where Ex - induced potential, V

   B - magnetic induction strength, T

   D - pipe inner diameter, m

   v - average velocity of liquid, m/s

However, volume flow rate qv Equal to the velocity of the fluid v And pipeline cross section area (π D ²) /4 The product of( one )Substituting into the formula, we can get the following result:

Qv=(π D/4B)* Ex -------- - Formula( two

It can be seen from the above formula that the diameter of the pipe D The magnetic induction intensity has been determined and maintained B The relationship between the measured volume flow rate and the induced potential is linear. If an electrode is inserted on both sides of the pipe, the induced potential can be introduced Ex The volume flow can be obtained by measuring the potential.

According to Faraday electromagnetic induction principle, a pair of detection electrodes are installed on the pipe wall perpendicular to the axis and magnetic line of force of the measuring tube. When the conductive liquid moves along the axis of the measuring tube, the conductive liquid cuts the magnetic line of force and generates an induced potential. The induced potential is detected by two detection electrodes, and the value is in positive proportion to the flow rate

E=B·V·D·K

Where: E - induced potential;

K - coefficient related to magnetic field distribution and axial length;

B - magnetic induction strength;

V - average velocity of conductive liquid;

D - electrode spacing; (measuring inner diameter of tube)

The sensor will induce an electric potential E As a flow signal, it is transmitted to the converter. After signal processing such as amplification, transformation and filtering, the instantaneous flow and cumulative flow are displayed by dot matrix LCD with backlight. The converter has 4~20mA Output, alarm output and frequency output RS four hundred and eighty-five Communication interface, and support HART and MODBUS agreement.

Note: the parameters of different electromagnetic flow meters are slightly different. Please check the manual when using.

According to Faraday's law of electromagnetic induction, when the magnetic induction intensity is 0 B In a uniform magnetic field perpendicular to the direction of the magnetic field, place an inner diameter of D When the velocity of the liquid in the pipe is not conductive v When flowing, the conductive fluid cuts the magnetic line of force . If a pair of electrodes are installed at both ends of the pipe section perpendicular to the diameter of the magnetic field, it can be proved that as long as the velocity distribution in the pipe is axisymmetric, the induced electromotive force between the two electrodes will be generated

e=KBDv (3-36)

Where, v Is the average velocity on the pipe section, k Is the instrument constant. Thus, the volume flow rate of the pipeline is obtained as follows:

qv= πeD/4KB (3-37)

It can be seen from the above formula that the volume flow rate qv And induced electromotive force e Tube and inner diameter measurement D It has a linear relationship with the magnetic induction intensity of the magnetic field B It is inversely proportional to other physical parameters. This is the measurement principle of electromagnetic flowmeter.

What needs to be explained is that to make the formula (3 37) It is strictly true that the measurement conditions of electromagnetic flowmeter must meet the following assumptions:

① The magnetic field is a constant magnetic field with uniform distribution ;

② The velocity distribution of the measured fluid is axisymmetric ;

③ The measured liquid is nonmagnetic ;

④ The conductivity of the measured liquid is homogeneous and isotropic.

 

Yj-lde series electromagnetic flowmeter The product features are as follows:

1. It is not affected by the change of fluid density, viscosity and temperature;

2. There is no obstructed flow part and pressure loss in the measuring pipe, and the requirement of straight pipe section is low;

3. Series nominal diameter DN15.5 DN3003 There are many kinds of sensor lining and electrode materials;

4. The converter adopts novel excitation mode, with low power consumption, stable zero point and high accuracy. The flow range can reach one thousand five hundred and three one

5. The transducer and sensor can be integrated or separated;

6. The converter adopts sixteen Bit high performance microprocessor, 2x16LCD Display, convenient parameter setting and reliable programming;

7. The flow meter is a two-way measurement system with three integrators: total forward, total reverse and total difference. It can display, reverse, and multiple outputs: current, pulse, digital communication HART agreement;

8. The converter is surface mounted (SMT) It has the function of self-test and self diagnosis;

 

Yj-lde series electromagnetic flowmeter Main technical parameters:

Executive Standards

JB T 9248—1999

Nominal diameter

fifteen twenty twenty-five thirty-two forty fifty sixty-five eighty one hundred one hundred and twenty-five one hundred and fifty two hundred two hundred and fifty three hundred three hundred and fifty
four hundred four hundred and fifty five hundred six hundred seven hundred eight hundred nine hundred one thousand one thousand and two hundred one thousand and four hundred one thousand and six hundred
one thousand and eight hundred two thousand two thousand and two hundred two thousand and four hundred two thousand and six hundred two thousand and eight hundred three thousand

Maximum velocity

15m s

accuracy

DN15 DN600

Indication value: ±0.35 ( Current Speed ≥1m s) ±3mm s( Current Speed <0.99m s)

DN700—DN3000

Indication ±0.53 ( Current Speed ≥0.83m S) ±4mm s( Current Speed <0.83m S)

Fluid conductivity

≥5uS cm

Nominal pressure

4.0MPa

1.6MPa

1.0MPa

0.6MPa

six point three 10MPa

DNl5 DN150

DNl5 DN600

DN200 DN1000

DN700 DN3000

Special order

ambient temperature

sensor

—25 ten sixty

Converter and all in one

—10 ten sixty

Lining material

Polytetrafluoroethylene, polychloroprene, polyurethane, perfluoroethylene propylene (F46) Screening PFA

Maximum fluid temperature

shape

seventy

Separable type

Polychloroprene rubber lining

eighty one hundred and twenty ( Note when ordering )

Polyurethane lining

eighty

PTFE lining

one hundred one hundred and fifty ( Note when ordering )

Perfluoroethylene propylene (F46)

Screening PFA

Signal electrode and grounding electrode materials

stainless steel 0Crl38Nil2M02Ti Hastelloy C Hastelloy B Titanium, tantalum, platinum / iridium alloy, stainless steel coated tungsten carbide

Electrode scraper mechanism

DN300—DN3000

Connection flange material

carbon steel

Flange grounding material

stainless steel 1Crl8Ni9Ti

Imported protective flange material

DN65—DNl50

stainless steel 1Crl8Ni9Ti

DN200 DNl600

Carbon steel and stainless steel 1Crl8Ni9Ti

Enclosure protection

DNl5 DN3000 Separate rubber or polyurethane lined sensors

IP65 or IP68

Other sensors —— Type flowmeter and separate converter

IP65

spacing ( Separable type )

The distance between transducer and sensor is not more than 100m

 

Yj-lde series electromagnetic flowmeter Flow range:

caliber mm

Flow range m3/h

caliber mm

Flow range m3/h

φ15

0.061~6.361

φ450

fifty-seven point two three one five thousand seven hundred and twenty-two point six five one

φ20

zero point one one one eleven point three one

φ500

seventy point six five one seven thousand and sixty-five point zero zero one

φ25

zero point one eight one seventeen point six six one

φ600

one hundred and one point seven four one ten thousand one hundred and seventy-three point six one

φ40

zero point four five one forty-five point two two one

φ700

one hundred and thirty-eight point four seven one thirteen thousand eight hundred and forty-seven point four one

φ50

zero point seven one one seventy point six five one

φ800

one hundred and eighty point eight six one eighteen thousand and eighty-six point four one

φ65

one point one nine one one hundred and nineteen point four one

φ900

two hundred and twenty-eight point nine one one twenty-two thousand eight hundred and ninety point six one

φ80

one point eight one one one hundred and eighty point eight six one

φ1000

four hundred and six point nine four one forty thousand six hundred and ninety-four point four one

φ100

two point eight three one two hundred and eighty-two point six zero one

φ1200

five hundred and fifty-three point nine zero one fifty-five thousand three hundred and eighty-nine point six one

φ150

six point three six one six hundred and thirty-five point eight five one

φ1600

seven hundred and twenty-three point four six one seventy-two thousand three hundred and forty-five point six one

φ200

eleven point three one one thousand one hundred and thirty point four one

φ1800

nine hundred and fifteen point six two one ninety-one thousand five hundred and sixty-two point four one

φ250

seventeen point six six one one hundred and seventy-six point two five one

φ2000

one thousand one hundred and thirty point four one one hundred and thirteen thousand and forty point zero zero one

φ300

twenty-five point four three one two thousand five hundred and forty-three point four zero one

φ2200

one thousand three hundred and sixty-seven point seven eight one one hundred and thirty-six thousand seven hundred and seventy-eight point four one

φ350

thirty-four point six two one three thousand four hundred and sixty-one point eight five one

φ2400

one thousand six hundred and twenty-seven point seven eight one one hundred and sixty-two thousand seven hundred and seventy-seven point six one

φ400

forty-five point two two one four thousand five hundred and twenty-one point six one

φ2600

one thousand nine hundred and ten point three eight one one hundred and ninety-one thousand and thirty-seven point six one

 

Yj-lde series electromagnetic flowmeter Electrode selection:

Electrode material

Corrosion resistance and wear resistance

stainless steel 0Crl8Nil2M02Ti

It is suitable for industrial water, domestic water, sewage and other weakly corrosive media. It is suitable for petroleum, chemical, steel and other industrial sectors and municipal, environmental protection and other fields.

Hastelloy B

It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as non chlorinated acid, alkali and non oxidizing salt solution such as sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.

Hastelloy C

It can resist the corrosion of non oxidizing acid, such as nitric acid, mixed acid, or mixed medium of chromic acid and sulfuric acid, and also resistant to oxidizing salts such as: Fe ,”、、 Cu ”Corrosion with or containing other oxidants, such as hypochlorite solution higher than normal temperature and seawater corrosion

titanium

Resistant to sea water, various chlorides and hypochlorites, oxidizing acids ( Including fuming sulfuric acid ) Organic acid and alkali. It is not resistant to pure reducing acid ( Such as sulfuric acid, hydrochloric acid ) But if the acid contains oxidant ( Such as nitric acid Fc ++、 Cu ++ ) The corrosion is greatly reduced.

tantalum

It has excellent corrosion resistance and is similar to glass. In addition to hydrofluoric acid, fuming sulfuric acid, alkali, almost resistant to cutting chemical media ( It includes hydrochloric acid, nitric acid and boiling point l 50 Sulfuric acid below ℃ ) Corrosion. In alkali; corrosion resistant.

Platinum / titanium alloy

Almost able to cut chemical media, but not suitable for aqua regia and ammonium salts.

Tungsten carbide coated stainless steel

It is used for non corrosive and strong wear medium.

Note: due to the variety of media, and its corrosivity is affected by complex factors such as temperature, concentration, flow rate, etc., this table is only for reference. Users should make their own choice according to the actual situation. If necessary, the corrosion resistance test of the materials to be selected, such as coupon test, should be carried out

 

Yj-lde series electromagnetic flowmeter Lining selection:


Lining material

main performance

Maximum medium temperature

Scope of application

- body type

Separable type

 

Polytetrafluoroethylene( F4)

It is a kind of plastic with the most stable chemical properties. It is resistant to boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia, as well as strong alkali and various organic solvents. It is not resistant to the corrosion of chlorine trifluoride, high temperature chlorine trifluoride, high flow rate liquid fluorine, liquid oxygen and self oxygen.

seventy

one hundred one hundred and fifty ( Special order required )

one , concentrated acid, alkali and other strong corrosive media. two Health media.

Perfluoroethylene propylene( F46)

with F4 The wear resistance and negative pressure resistance are higher F4

ditto

 

Polyfluoroethylene( Fs)

The upper limit of applicable temperature is lower than that of polytetrafluoroethylene, but the cost is also lower.

eighty

 

Polychloroprene rubber

one Excellent elasticity, high breaking force and good wear resistance. two It is resistant to acid, salt and oxidation.

eighty one hundred and twenty ( Special order required )

Water, sewage and slurry with weak abrasion resistance.

Polyurethane rubber

one Excellent wear resistance.  
two
Poor corrosion resistance.

eighty

Mineral slurry, coal slurry and mud with neutral strong abrasion

 

 

Yj-lde series electromagnetic flowmeter Complete selection:

model

caliber

 

YJ-LDE

15~2600

 

 

Code name

Installation form

 

Y

Integrated

F

Split style

 

Code name

Converter model

ZA

circular

ZB

square

 

Code name

output signal

I.4

4~20mA

f

frequency 1KHz

Rs

Serial communication( four hundred and eighty-five

C

Output control

 

  Code name

Explosion proof requirements

 N

No explosion proof

EX

Explosion proof (split type only)

 

Code name

Medium temperature

T1

≤65

T2

≤120

T3

≤180 ( Split type only)

 

Code name

Lining material

NE

Chloroprene rubber( ≤65 ℃)

PTFE

Polytetrafluoroethylene( ≤189 ℃)

PVC

Polyvinyl chloride( ≤70 ℃)

 

Code name

Electrode material

316L

stainless steel

HC

Hastelloy C

HB

Hastelloy B

Ti

titanium

Ta

tantalum

 

Yj-lde series electromagnetic flowmeter Installation diagram:

 Installation of electromagnetic flowmeter

1. Select the straight pipe section full of liquid, such as the vertical section of the pipeline (the flow direction is from bottom to top) or the horizontal pipe full of liquid (the lowest part in the whole pipeline is appropriate). During the installation and measurement process, the non full pipe shall not occur.

2. The measuring position should be set at upstream and greater than 5D And downstream 3D Straight pipe section.

3. The measurement points should be as far away as possible from the pump, valve and other equipment to avoid the interference to the measurement.

4. The measurement points should be as far away from high-power radio station and strong magnetic field interference source as possible.

 

Yj-lde series electromagnetic flowmeter Quality commitment:
 Production of electromagnetic flowmeter

Jinhu Yijia Instrument Co., Ltd. is mainly engaged in electromagnetic flowmeter, vortex flowmeter, orifice flowmeter, magnetic flap level gauge, glass plate level gauge and other products, and provides a one-year warranty for all products. In case of product quality problems (excluding wearing parts or accessories) within one year, they shall be repaired free of charge, and technical support shall be provided free of charge.

Consultation hotline 0517-86936880 15358661880