Precession Vortex Flowmeter

 Precession Vortex Flowmeter

Yjlux series Precession Vortex Flowmeter Using the latest micro processing technology , It has a wide range of maintenance and simple operation , Easy to install and use , Its main technical indexes have reached the advanced level of similar products abroad. It integrates pressure and temperature detection and compensation calculation. It has the advantages of high measurement accuracy, wide flow range, no movable parts, good anti vibration and anti pulsating flow performance, small volume, light weight and easy to use. Precession Vortex flowmeter is an ideal instrument for gas measurement in petroleum, chemical, electric power, metallurgy and city gas network.

 

Yjlux series Precession Vortex Flowmeter working principle:
 Working principle of Precession Vortex Flowmeter

When the fluid passes through the vortex generator composed of spiral blades, the fluid is forced to rotate violently around the generating body axis to form vortex. When the fluid enters the diffusion section, the vortex flow is affected by the backflow, and begins to make a second rotation, forming a gyroscopic vortex precession phenomenon. The precession frequency is directly proportional to the flow rate and is not affected by the physical properties and density of the fluid. The flow rate is known by measuring the precession frequency of the second rotation of the fluid. In addition, good linearity can be obtained in a wide flow range. The flow calculation formula is as follows:

K=f/q

Where: K ——Flow meter coefficient l/m³

F -- vortex frequency Hz

Q -- volume flow rate m³/s

The instrument coefficient of the flowmeter has nothing to do with the temperature, pressure, composition and physical properties (density and viscosity) of the fluid in a certain range of structural parameters and specified Reynolds number.


The flowmeter is composed of sensor and conversion display instrument.

1. The sensor includes a vortex generator, a detection element, a rectifier and a shell.

The vortex generator is composed of a specific spiral blade, which is fixed at the front end of the shell contraction section, forcing the fluid to produce strong vortex flow.

The detection element is installed near the throat of the expansion tube, and the frequency signal of vortex precession can be measured by using thermal, piezoelectric, strain, capacitance or optical fiber detection elements.

The rectifier is fixed at the outlet of the flowmeter body, and its function is to eliminate the vortex flow, so as to reduce the influence of downstream flow pattern on instrument measurement.

The shell is designed into a certain shape of flow channel to form vortex, fix and protect the internal parts and components, and connect with the pipeline through flange.

2. Conversion display instrument

After amplification, filtering and shaping, the weak voltage signal detected by the piezoelectric sensor becomes a pulse signal whose frequency is proportional to the flow rate, and then is counted and displayed by the display instrument. The display instrument is equipped with export interface to output various signals. The measured gas medium can be compensated for temperature and pressure, converted into volume flow under standard conditions, and displayed.

 

Yjlux series Precession Vortex Flowmeter Main features:

1. No mechanical rotating parts, long-time work without maintenance.

2. The requirements for straight pipe sections are very low.

3. Low power consumption

4. High precision, up to ± 1.5%

5. The data is saved automatically after power failure

6. With password protection function

 

Yjlux series Precession Vortex Flowmeter Technical parameters:

Instrument model

YJLUX type

Accuracy class

one point five level ~1 level

Nominal diameter

DN20~DN200

monitor

Standard configuration

Temperature and pressure compensation

Optional

signal output

Working condition pulse, calibration pulse or 4-20mA

External power supply

+24VDC , ripple ≤5% For signal output

Internal power supply

The built-in lithium battery is only used for field display

communication interface

Optional RS485

Communication protocol

MODBUS

Sensor material

Cast aluminum or stainless steel

Explosion proof grade

ExdIIBT4

Protection level

IP65

Power consumption of the whole machine

External power supply < 1W  Internal power supply < 0.3W

Installation method

Flange mounting

Nominal pressure

1.6MPa Or customized

Medium temperature

-20 ~+80

ambient temperature

-30 ~+60

relative humidity

5%~95%

atmospheric pressure

70KPa~106KPa


Yjlux series Precession Vortex Flowmeter measuring range :

  Instrument specifications

  Nominal diameter

  measuring range

 Qmax Time pressure loss

LUX-20

DN20

1.2-15 m3/h

3.3 KPa

LUX-25

DN25

2.5-30 m3/h

2.1 KPa

LUX-32

DN32

4.5-60 m3/h

2.9 KPa

LUX-50

DN50

10-150 m3/h

3.9 KPa

LUX-80

DN80

28-400 m3/h

3.7 KPa

LUX-100

DN100

50-800 m3/h

5.9 KPa

LUX-150

DN150

150-2250 m3/h

11 KPa

LUX-200

DN200

360-3600 m3/h

16 KPa

 

Yjlux series Precession Vortex Flowmeter Product selection:

 

Code name

function

N

No temperature and pressure compensation

Y

With temperature and pressure compensation

 

Code name

Output model

F1

4-20mA Output (two wire system)

F2

4-20mA Output (three wire system)

F3

RS485 communication interface

 

Code name

function two

E1

one level

E2

one five level

T

normal atmospheric temperature

P1

one 6Mpa

P2

two 5Mpa

P3

four 0Mpa

D1

inside 3.6V power supply

D2

DC24V power supply

B1

stainless steel

B2

aluminium alloy

 

Yjlux series Precession Vortex Flowmeter Dimensions:

Nominal diameter

DN(mm)

Nominal pressure

(MPa)

Dimensions (mm)

Body material

weight

(kg)

 

 

Body length L

height H

stainless steel

aluminium alloy

 

 

 

twenty

1.6/2.5/4.0

one hundred and eighty

three hundred and forty-seven

 

five

six point three ten sixteen

one hundred and eighty

three hundred and fifty-seven

 

 

 

twenty-five

1.6/2.5/4.0

two hundred

three hundred and sixty-seven

 

seven

six point three ten sixteen

two hundred

three hundred and seventy-eight

 

ten

 

thirty-two

1.6/2.5/4.0

two hundred and thirty

three hundred and eighty-three

 

nine

six point three ten sixteen

two hundred and thirty

four hundred and two

 

twelve

 

fifty

1.6/2.5/4.0

two hundred and thirty

four hundred and three

 

eleven

six point three ten sixteen

two hundred and sixty

four hundred and twenty-one

 

fourteen

 

eighty

one point six

three hundred and thirty

four hundred and thirty-eight

 

eleven

2.5/4.0

three hundred and thirty

four hundred and thirty-eight

 

eighteen

 

six point three ten sixteen

three hundred and thirty

four hundred and forty-six

 

twenty-one

 

one hundred

one point six

four hundred and ten

four hundred and sixty-eight

 

 

fourteen

2.5/4.0

four hundred and ten

four hundred and seventy-five

 

eighteen

 

six point three ten sixteen

four hundred and ten

four hundred and eighty-three

 

thirty-three

 

one hundred and fifty

one point six

five hundred and eighty-five

five hundred and forty-two

 

twenty-one

2.5/4.0

five hundred and eighty-five

five hundred and forty-nine

 

fifty-two

 

six point three

five hundred and eighty-five

five hundred and seventy-two

 

seventy-two

 

two hundred

one point six

seven hundred

six hundred and eighteen

 

forty-one

two point five

seven hundred

six hundred and twenty-six

 

one hundred and seventeen

 

four

seven hundred

six hundred and thirty-four

 

one hundred and twenty-seven

 

 

Yjlux series Precession Vortex Flowmeter Installation requirements:

In order to make the Precession Vortex Flowmeter work in a normal state, the installation and use personnel must understand the specific structure, characteristics and flow signal conversion of the installed instrument, understand the role of each link in the signal transmission process, and install and use according to the product manual. Generally speaking, the following points should be paid attention to in the installation and use of Precession Vortex flowmeter.

1) Choose a reasonable installation site. Installation site should avoid strong power equipment, high frequency equipment, strong power switch equipment ; Avoid the influence of high temperature heat source and radiation heat source ; Avoid the influence of high temperature and strong corrosive atmosphere : Avoid strong vibration, and installation, wiring, maintenance is convenient. In the upstream and downstream of the sensor, the vibration caused by the long pipe must be eliminated.

2) Generally, the instrument should be installed horizontally, and the flow direction of the measured fluid should be consistent with the arrow indicating the flow direction on the shell. It can also be installed vertically or obliquely. When measuring liquid, make sure that the sensor is always fully filled with liquid. In order not to affect the normal transmission of fluid during maintenance, it is suggested to add a bypass in the installation section of the instrument.

3) In principle, it is allowed that there is no straight pipe section before and after the flowmeter, but it is generally required that there is one in front of the instrument 3D The length of the straight pipe is behind the instrument 1D Length of straight pipe. Special requirements 5D and 3D Length. When the radius of single bend or double bend is greater than 1.8D The straight pipe section can not be used before and after the flowmeter. The length of straight pipe required for various pipe installation conditions is shown in the figure below.

4) Temperature and pressure compensation can be used when measuring gas or steam. The installation position of thermometer and pressure gauge is shown in the figure.

5) When there are impurities in the measured fluid, a filter or filter screen should be installed in front of the instrument, but the requirements of straight pipe section in front of the instrument should still be ensured.

6} When measuring a small amount of gas-liquid two-phase flow with different phases, the sensor installation method is introduced. When measuring liquid, there may be a small amount of gas phase in the pipeline, the content of which does not exceed the specified gas-liquid two-phase fluid. In order to prevent the gas from staying in the sensor, a gas separator must be installed. When measuring gas, when the pipeline is subject to the condensate that may be produced by the measured gas and the unstable liquid phase in the gas which has not been removed, it is better to install vertically to prevent the liquid from staying in the sensor. When measuring high and low temperature fluid, the sensor itself should have effective measures to hold.

7) The volume flow of the measured gas measured by the instrument is the actual flow rate of the measured gas under the working state. If the actual flow rate is converted into the standard flow rate under the standard state, the following formula can be used, four P is the volume flow rate in the standard state ;4, Is the volume flow rate in the working state ;ho Is the absolute pressure of the gas under standard condition ;To Is the thermodynamic temperature of the gas under standard condition ; Household is the absolute pressure of the measured gas under working condition ;T Is the thermodynamic temperature of the gas to be measured under working conditions ;Z Is the compression coefficient of the measured gas under working condition.

8) When the pipeline is long and vibration may occur, fixed supports should be installed upstream and downstream of the flowmeter to prevent pipeline vibration. According to experience, the flow measurement value is easily affected by air flow pulsation and pressure change.

9) Volume flow meter coefficient K vn Mass flow meter coefficient K,,,o It is calibrated and determined at normal temperature before the instrument leaves the factory. When the instrument is in calibration condition, it is quite different from the working condition of the instrument K , and K "Correction should be made, and the correction method for instrument coefficient is the same as that for vortex flowmeter.

 Installation diagram of Precession Vortex Flowmeter

 

Yjlux series Precession Vortex Flowmeter Quality commitment:

Jinhu Yijia Instrument Co., Ltd. is mainly engaged in electromagnetic flowmeter, vortex flowmeter, orifice flowmeter, magnetic flap level gauge, glass plate level gauge and other products, and provides a one-year warranty for all products. In case of product quality problems (excluding wearing parts or accessories) within one year, they shall be repaired free of charge, and technical support shall be provided free of charge.

Consultation hotline 0517-86936880 15358661880